Immersion Probes

Immersion Probes

Immersion Probes

Rugged line of 3/4″ -3/4″ & 3/4″ – 1″ MNPT pH & ORP sensors for in-line and standpipe applications. Available in slurry / viscous, sulphide, high temperature, cyanide, organic applications and many other difficult process applications. IPI sensors are manufactured in the US and their high quality ensures they are unsurpassed in any mining applications.

Overview
IPI-ASTI Probes offer unique solutions for process measurement problems:

  • Best reference lifetime in process industry through nonporous cross linked conductive polymer
  • Rugged industrial grade sensors can operate in a temperature range from -30 to 150 degrees Centigrade
  • Application Specific pH glasses service processes such as such as acid/fluoride, saturated sodium, ultrapure water, cyanide, sulfide, high / ultra high temperature, slurry/viscous materials, paper and pulp
  • Each standard sensor selection and/or special sensor design are based upon customer application information
  • Wide range of plastic housing configuration from inexpensive CPVC/PVC, General Purpose RYTON, to the extremely chemically & thermally resistant UltemTM (PEI) and PEEK

Supported Meters

Replacement Sensors
REQUIRING  
Integrated
Preamplifiers

Instruments with preamplifiers are supplied with the
appropriate internal temperature compensation, solution ground & integrated
(embedded) OEM compatible high-impedance CMOS operational amplifiers
(a.k.a. preamplifiers).  Not that some manufacturers can support
sensors with or without preamplifiers on the same meter.  Appropriate
sensor hook-up schematics are provided with each sensor, and can
be found this web site.

Replacement Sensors
NOT
REQUIRING
 Integrated
Preamplifiers

Instruments without preamplifiers are supplied with the
appropriate internal temperature compensation and/or solution ground signals.
 Appropriate sensor hook-up schematic are provided with each
sensor, and can be found here.

Fully
Supported Hardware

Electro-Chemical Devices (100%
Compatible, FULL SUPPORT)

       T-20, T-21, T-27, T-28, T-29,
T-30, C-22

Foxboro (100% Compatible, FULL SUPPORT)
       870IT , 873, 873DPX,
875IT

Jenco (100% Compatible, FULL SUPPORT)
       6311

Leeds and Northrup (Honeywell)
(100% Compatible, FULL SUPPORT)

       7030, 7075, 7076, 7079, 7081,
7082 , 7083, 7084, 7096, 9782

Uniloc-Rosemount (100% Compatible,
FULL SUPPORT)

       1000, 1001, 1002, 1003, 1050,
1181 , 1054, 1054A,

       1054B, 1055, 2081, 3081, 81,
54pH/ORP, 54e, 5081, XMT

Fully
Supported Hardware

Endress+Hauser (100%
Compatible, FULL SUPPORT)

       CPM 223/253, CPM 152, CPM 153, CPM
280, CPM 431

Mettler Toledo – Ingold (100%
Compatible, FULL SUPPORT)

       1120, 1140, 2050, 2100, 2220, 2400, 2500, 2800X


     
M700,
pH 1140, pH 2050e, pH 2100-PA, pH 2100e

TBI-Bailey Controls (100%
Compatible, FULL SUPPORT)

       TB515, TBN580,
TB701/702, TB82pH, TB84pH
       4630,
4631, 4635, 4636, AX416, AX436, AX468, AX460, AX466

Supported Hardware
with Known issues

Uniloc-Rosemount (Limited Compatability,
Some Known Issues)

       1054, 1054A
& 1054B

Great Lakes Instruments (Most models
supported, Some minor known issues)

       33, 53, 60, 62, 63, 70, 83,
90, 95, 570, 670

       671, 690, 691, 692,
P33, P53, P63, Pro-Series P3

Signet (Limited Compatability,
Some Known Issues)

       710 et. al., 2720, 9030,
9040, 8710, 8750, 5700

IC Controls (Limited Compatibility,
Some Known Issues)

       650,
652, 653, 653-9, 654, 655,
656, 657

Aquametrix (Most models
supported, Some minor known issues)

       SHARK, 2200P,
2200R

Supported
Hardware
with Known issues

Johnson Yokogawa (Limited Compatibility,
Some Known Issues)

       pH/ORP 200, pH/ORP
400, pH/ORP 202, pH/ORP 402
       pH150,
pH100, OR100

 

PLEASE INQUIRE FOR ANY INSTRUMENTATION NOT LISTED

Applications

Standard Applications

  • Acid/Fluoride 
  • High / Ultra High Temperature 
  • Paper/Pulp 
  • Slurry/Viscous Materials 
  • Saturated Sodium 
  • Oxidation Reduction Potential 
  • Sulfides 
  • Ultrapure Water 
  • General Purpose 

 Special Applications

  • Organic Solvents Resistant
  • Cyanide Resistant 
  • Dissolved Gases:
  • Cl2, ClO2, NH3,
    SO2 / SO3 / NOX Resistant

View selected pH, ORP & Ion Selective
Measurement and Control Case Studies (Application Bulletins)

LIMITS &
CAPABILITIES (PARTIAL LIST ONLY)

pH &  ORP
MEASUREMENTS

  • Fluorides up
    to 50,000 PPM and -0.5 pH
  • Sulfides
    up to Saturation
  • Cyanides
    up to 500 PPM
  • High pH
    range up to 14.5
    (with
    ASTI calibration procedures and buffers)
  • Low pH
    range up to -0.5
    (with ASTI calibration procedures and buffers)
  • Low
    Temperature up to -30 oC
  • High
    Temperature up to 150 oC
  • High
    Pressure up to 150 p.s.i.
  • Solids
    Content up to 12% Consistency Pulp
  • Almost
    All Organic Chemical Mixtures (Minimum 1-2 % aqueous
    content)
  • ORP Measurements
    in Completely Non-Aqueous Medium
  • Bleaching Applications using Chlorine and Chlorine
    Dioxide
  • Sterilization
    Applications using Peroxide, Ozone & Dissolved O2

PLEASE INQUIRE FOR ANY APPLICATIONS NOT LISTED HERE

Selection Guide

Iotron TM Sensor
Selection Guide

3/4″-1″ MNPT
Sensor Body Housing Configuration

Sensor Description RYTON RYTON ULTEM PEEK
General 
Purpose
6052 (Specs) 6051 (Specs) 6031 (Specs) 6041 (Specs)
High & Low
Temperature
Not Available Not Available 6131 (Specs) 6141 (Specs)
Ultra High / Low
Temperature
Not Available Not Available Not Available 6241 (Specs)
Slurry 
Viscous Material 
6352 (Specs) 6351 (Specs) 6331 (Specs) 6341 (Specs)
Acid/ Fluoride 
Resistant
6452 (Specs) 6451 (Specs) 6431 (Specs) 6441 (Specs)
Paper/ Pulp 
Resistant
Not Available 6551 (Specs) 6531 (Specs) 6541 (Specs)
Sulfide 
Resistant
Not Available 6651 (Specs) 6631 (Specs) 6641 (Specs)
Ultrapure
Water
Not Available 6751 (Specs) 6731 (Specs) 6741 (Specs)
ORP 6852 (Specs) 6851 (Specs) 6831 (Specs) 6841 (Specs)
Saturated Sodium 
Resistant
6952 (Specs) 6951 (Specs) 6931 (Specs) 6941 (Specs)

Iotron TM Sensor
Selection Guide

3/4″-3/4″ MNPT
Sensor Body Housing Configuration

Sensor Description CPVC CPVC CPVC ULTEM PEEK
General 
Purpose
2012 (Specs) 6011 (Specs) 6012 (Specs) 6032 (Specs) 6042 (Specs)
High Temperature Not Available Not Available Not Available 6132 (Specs) 6142 (Specs)
Ultra High 
Temperature
Not Available Not Available  Not Available Not Available 6242 (Specs)
Slurry 
Viscous Material 
2312 (Specs)

6311 (Specs)

6312 (Specs) 6332 (Specs) 6342 (Specs)
Acid/ Fluoride 
Resistant
2412 (Specs)

6411 (Specs)

6412 (Specs) 6432 (Specs) 6442 (Specs)
Paper/ Pulp 
Resistant
Not Available Not Available 6512 (Specs) 6532 (Specs) 6542 (Specs)
Sulfide 
Resistant
Not Available Not Available 6612 (Specs) 6632 (Specs) 6642 (Specs)
Ultrapure
Water
Not Available Not Available 6712 (Specs) 6732 (Specs) 6742 (Specs)
ORP 2812 (Specs)

6811 (Specs)

6812 (Specs) 6832 (Specs) 6842 (Specs)
Saturated Sodium 
Resistant
2912 (Specs)

6911 (Specs)

6912 (Specs) 6932 (Specs) 6942 (Specs)

Sensor Options

Immersion & Twist
Lock Sensor Options

  • All Immersion sensors come standard with protective
    tines (guard).
     Protective tines (guard) can be removed at no additional charge (“NG”
    option)
  • All Twist Lock sensors come standard without protective
    tines (guard).
     Protective tines (guard) can be added at no additional charge (“GR”
    option)
  • All Immersion and Twist Lock sensors can have the
    waterproofing option added for subemrsible sensor installations
  • Link
    to Submersible Assemblies
    (with WaterProofing Option)
  • All sensors may be mounted from either front or rear
    MNPT
    threading
  • Sensors can be mounted with a pipe stand for immersion
    installations or flow-through tee
    configuration for inline installations
  • Fast 
    temperature compensation response may be desired for some inline flow
    cell installations with variable temperature conditions (IotronTM
    AccuTempTM)

 

THE COMPLETE ASTI
PART NUMBERING GUIDE

APPENDIX “A”

Custom Applications

Add-On Alpha Prefix

Dissolved Chlorine Gas

“C”

Dissolved Ammonia Gas

“A”

Organic Media
Applications

“L”

Teflon Silicone
Required*

“TS”

Triple Junction*

“TJ”

Position Insensitive Assembly*

“H”

Mid-Level HF Resistant

“MF”

High-Level HF Resistant

“HF”

Accu-Temp Option for
Fast Temperature Response*

“X”

Low Impedance Option

“GP”

Custom
Configurations

Add-On Alpha Prefix

Removal of Sensor Guard
(For Immersion or Valve Retractable Series Only)

“NG”

Additional of Sensor
Guard (for Twist Lock Series Only)

“GR”

Solution Ground
Addition (Indicated for Sensors Without Preamplifiers Only)*